< Prev | Contents | Next > |
2.2. Fluid Hydraulics
![]() |
2.2.7. Nozzles Conversion |
Task is used to select bit nozzles count and diameters using list of available nozzles in the reference if desired total number of nozzles and TFA are defined. Estimated flow area of selected nozzles is displayed in the field 'Bit Nozzles Area' to be compared with desired TFA.
Input Values | ||
![]() |
Desired Nozzles Area | Desired total flow area of nozzles |
![]() |
Nozzles Count [1..6] | Desired Nozzles Count from 1 to 6 |
Results | ||
![]() |
Bit Nozzles Area | Estimated total flow area of nozzles |
![]() |
Nozzles quantities and counts | Quantity of each size of nozzles |